View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity/public exploits are available Vendor: Edimax Equipment: IC-7100 IP Camera Vulnerability: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to send specially crafted requests to achieve remote code execution on the device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Edimax products are affected: IC-7100 IP Camera: All versions 3.2 VULNERABILITY OVERVIEW 3.2.1 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') CWE-78 Edimax IC-7100 does not properly neutralize requests. An attacker can create specially crafted requests to achieve remote code execution on the device CVE-2025-1316 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A CVSS v4 score has also been calculated for CVE-2025-1316. A base score of 9.3 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N). 3.3 BACKGROUND CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities Sector COUNTRIES/AREAS DEPLOYED: Worldwide COMPANY HEADQUARTERS LOCATION: Taiwan 3.4 RESEARCHER Akamai SIRT reported this vulnerability to CISA. 4. MITIGATIONS Edimax has not responded to CISA requests to coordinate the vulnerability. Affected users are encouraged to reach out to Edimax customer support. CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. 5. UPDATE HISTORY March 4, 2025: Initial Publication
Analysis Summary
# Vulnerability: Edimax IC-7100 IP Camera Vulnerabilities
## CVE Details
- CVE ID: Not specified in the provided context.
- CVSS Score: Not specified in the provided context.
- CWE: Not specified in the provided context.
## Affected Systems
- Products: Edimax IC-7100 IP Camera
- Versions: Not specified in the provided context.
- Configurations: Not specified in the provided context.
## Vulnerability Description
The provided context identifies an ICS Advisory (ICSA-25-063-08) concerning vulnerabilities existing in the Edimax IC-7100 IP Camera. Specific technical details regarding the nature of the flaws (e.g., buffer overflow, authentication bypass) were not included in the text snippet.
## Exploitation
- Status: Unknown. The advisory classification does not indicate exploitation status.
- Complexity: Unknown.
- Attack Vector: Unknown.
## Impact
- Confidentiality: Unknown.
- Integrity: Unknown.
- Availability: Unknown.
## Remediation
### Patches
- Specific patches or firmware updates addressing ICSA-25-063-08 are **not detailed** in this summary context. Users should refer to the full advisory.
### Workarounds
- No specific workarounds were detailed in the provided text.
## Detection
- No specific Indicators of Compromise (IoCs) or detection methods were provided in this summary context.
## References
- Vendor advisories: Edimax (Specific link not provided)
- Relevant links:
- Full CISA Advisory: cisa.gov/news-events/ics-advisories/icsa-25-063-08