Schneider Electric EcoStruxure (Update A)

HIGH
CVSS 7.8
Date 2026-06-02T06:00:00+00:00
Source cisa-csaf
Published by CISA

// Description

We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.* Place all controllers in locked cabinets and never leave them in the “Program” mode.* Never connect programming software to any network other than the network intended for that device.* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.

// Vulnerabilities (1)

CVE ID CVSS Score Severity Description
CVE-2025-0327 7.8 high
CVE-2025-0327. CWE-269: Improper Privilege Management vulnerability exists for two services (of which one managing audit trail data and the other acting as server managing client request) that could cause a loss of Confidentiality, Integrity and Availability of engineering workstation when an attacker with standard privilege modifies the executable path of the windows services. To be exploited, services need to be restarted.

// Affected Products (6)

Vendor Product Asset Type Purdue Level Firmware
Schneider Electric Unknown engineering_workstation
L3
2020_R2
Schneider Electric Unknown engineering_workstation
L3
--
Schneider Electric Unknown engineering_workstation
L3
2020_R2
Schneider Electric Unknown engineering_workstation
L3
2020_R2
Schneider Electric Unknown engineering_workstation
L3
2020_R2
Schneider Electric Unknown engineering_workstation
L3
2023_v4.8.0.5715

// Remediations (4)

Mitigation: If customers choose not to apply the remediation provided above, they should immediately apply the f
If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: • Allow only admin user to configure windows service by restricting execute permission of sc.exe windows utility. • McAfee Application and Change Control software for application control to allow execution of whitelisted applications only. Refer to the Cybersecurity Application Note available https://www.se.com/ww/en/download/document/EIO0000004778/
Patch: Version v4.8.0.5715 of EcoStruxure Process Expert 2023 Software Package includes a fix for this vuln
Version v4.8.0.5715 of EcoStruxure Process Expert 2023 Software Package includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/65406-ecostruxure-processexpert/#software-and-firmware. Uninstall Previous Version 2023 (v4.8.0.5115) before installing Version 2023 (v4.8.0.5715). Version string could be found on engineering server console.
Mitigation: If customers choose not to apply the remediation provided above, they should immediately apply the f
If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:• Allow execute permission for service control Windows utility only to admin user.• McAfee Application and Change Control software for application control to allow execution of whitelisted applications only. Refer to the Cybersecurity Application Note available https://www.se.com/ww/en/download/document/EIO0000004778/
Patch: Version 2025 of EcoStruxure Process Expert for AVEVA System Platform 2025 Software Package includes
Version 2025 of EcoStruxure Process Expert for AVEVA System Platform 2025 Software Package includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/55570689-ecostruxure-process-expert-for-aveva-system-platform/#software-and-firmware