The Mendix Encryption module versions V10.0.0 and V10.0.1 define a specific hard-coded default value for the EncryptionKey constant, which is used in projects where no individual EncryptionKey was...
Multiple SICAM products are affected by unauthorized password reset and firmware downgrade vulnerabilities that could lead to privilege escalation and potential leak of information, namely: SICAM...
Omnivise T3000 contains multiple vulnerabilities that could allow an attacker to escalate privileges. Siemens Energy has released patches for several affected products and recommends to apply the...
SCALANCE M-800 family before V7.2.2 is affected by multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SCALANCE M-800 family before V8.1 is affected by multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
TIA Portal contains a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system...
SCALANCE M-800 family before V8.0 is affected by multiple vulnerabilities. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens...
NX (incl. NX student versions) before V2406.3000 contains an out-of-bounds read vulnerability that could be triggered when the application reads PRT files. If a user is tricked to open a malicious...
Parasolid and Teamcenter Visualization are affected by memory corruption vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a...
INTRALOG WMS before V4 is affected by vulnerabilities in the SQL Client-Server communication and in the .NET framework. Successful exploitation could allow an unauthenticated attacker located in...
Versions V5.0 through V7 of the Desigo CC product family (Desigo CC, Desigo CC Compact, Desigo CC Connect, Cerberus DMS), as well as the Desigo CC-based SENTRON powermanager, are affected by...
TIA Project-Server formerly known as TIA Multiuser Server contains an untrusted search path vulnerability that could allow an attacker to escalate privileges, when tricking a legitimate user to...
COMOS before V10.5 is affected by two local code execution vulnerabilities in the integrated Open Design Alliance Drawings SDK. Siemens has released a new version for COMOS and recommends to...
SINEC Traffic Analyzer before V2.0 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC Traffic Analyzer and recommends to update to the latest version.
Location Intelligence before V4.4 is affected by multiple vulnerabilities that could allow an attacker in an on-path position to read and modify data passed over the connection between legitimate...
Siemens Teamcenter Visualization and JT2Go are affected by an out of bounds read vulnerability in the APDFL library from Datalogics. If a user is tricked to open a malicious PDF file with the...
Teamcenter Visualization and JT2Go are affected by out of bounds read, stack exhaustion and null pointer dereference vulnerabilities that could be triggered when the application reads files in X_T...
SINEC NMS before V3.0 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC NMS and recommends to update to the latest version.
Siemens has released a new firmware version for SCALANCE X-200 and X-200 IRT switches that address Bad Alloc vulnerabilities in the underlying operating system and recommends to update to the...
Teamcenter Visualization and JT2Go are affected by out of bounds read and null pointer dereference vulnerabilities that could be triggered when the application reads files in X_T format. If a user...
Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in several industrial products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA...
SINUMERIK systems, that have been provisioned with Create MyConfig (CMC), are affected by a Insertion of Sensitive Information into Log File vulnerability. When using a CMC package on a NCU or on...
A vulnerability has been identified in the integrated S7-1500 CPU of SINUMERIK ONE and SINUMERIK MC products that could allow an attacker to cause a denial of service condition. In order to...
Several industrial devices are affected by two vulnerabilities that could allow an attacker to cause a denial of service condition via PROFINET DCP network packets under certain circumstances. The...
SINUMERIK ONE, SINUMERIK 840D sl and SINUMERIK 828D are affected by a privilege escalation vulnerability that could allow an authenticated local attacker to escalate their privileges in the...
Industrial Edge Management contains an Authorization Bypass vulnerability that could allow an unauthenticated remote attacker to impersonate other devices onboarded to the system. Siemens has...
SINEMA Remote Connect Client before V3.2 SP2 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Client and recommends to update to the latest version.
Multiple NULL pointer dereference vulnerabilities in the affected products could allow an attacker with network access to the webserver, to perform a denial of service attack. Siemens has released...
Siemens Tecnomatix Plant Simulation is affected by a stack-based buffer overflow vulnerability that could be triggered when the application reads files in SPP file format. If a user is tricked to...
Multiple vulnerabilities in the affected products could allow an unauthorized attacker with network access to the webserver of an affected products to perform a denial of service attack. Siemens...